- Battery guard system
- Emergency override switch provides a convenient way to restore power to your equipment by holding the button in.
- Protects communication equipment
- Low voltage detector (19 v)
- Over voltage protection (30 v)
- Automatic On/Off
- Very reliable & accurate
- Programmable with external DIP switch for selecting and adjusting time delay
- Built-in diagnostic red LED indicates timing functions active when flashing
- Engineered electronically for reverse polarity protection
- Potted compound construction. Solid state, sealed against vibration and moisture.
- Easy external connection with .250 male tab mating with .250 female disconnect
- Delay time range:from 15 minutes to 8 hours. Tolerance plus (+) or minus (-) 10%
- Allow 3-5 seconds for delay on break at ignition switch connection for delay activation
- For installation, connect both .250 male tabs (+) to the battery positive post and .250 male tab (-) to the battery negative post.
Connect the ignition switch .250 male tab to fuse block (AM/FM radio) or cigarette lighter.
Technical Specifications
| Length |
4 in. |
| Width |
2 in. |
| Height |
1.5 in. |
| Mounting Hole Center |
3.5in with #6 screws |
| Weight |
6 oz. |
| Enclosure Material |
Impact Resistant ABS thermoplastic |
Electrical Specifications
| Load Current Rate |
30 amps 12 VDC |
| Operating Voltage |
10 VDC min - 18 VDC max |
| Ignition Switch Trigger |
10.4 - 15.0 VDC, 10mA |
| Low Voltage Disconnect |
19 volts |
| Over Voltage Disconnect |
30 volts |
| Operating Temperature |
-40 F to +185 F |
| Stand-by Current |
6 mA |
| Operating Current |
100 mA |
Caution: An appropriate size fuse circuit breaker must be used to ensure safety.